LE-33-12 - SOLENOID LOCKS (LOCKED WHEN TURNED ON)

Nice Characteristics

Both front and rear surface attachment. (remove the cover when choosing the front surface attachment)
Can be locked with a remote control.
The protective cover is included in accessories. (this can be removed)
The locking verification switch is incorporated. (LE-33-10-S)

Specifications
Rated voltage: DC24V±5%
Duty cycle: 100% (continuous rating)
To be locked by turning on power (excitation locking type)
Ambient temperature: -5℃ to +40℃
(non-condensing)
Operating humidity range: 85%RH or less (non-dewing)

Specific Use
Pass boxes and various cases

Remarks
Rated of switch (resistance load) for
LE-33-10-S: AC125V 1A. DC30V 0.5A.
Make sure that the screw does not protrude from the solenoid installation surface.
The latch stroke, the retraction force and the extension force are value in the horizontal installation.
The rated voltage (continuous rating) is at a power consumption that causes the temperature of the coil to reach 65℃ when the ambient temperature is 40℃.
When continuously energized, the solenoid becomes hot (around 70℃). If there is a risk of it being touched, measures should be taken to prevent burns with consideration given to heat radiation.
Remove the load on the latch when operating electrically.
Solenoid has no polarity (+ / -).

Contact

Specifications

Tags: